Rolle gpu_fan_control im Host-Projekt: Systemdienst gnai-gpu-fan-control steuert beide Karten PCI-stabil aus der Junction-Temperatur (Anker 50/58/66/72/76C -> 0/80/140/200/255 PWM, 5s-Zyklus, fallende Hysterese, EXIT-Failsafe auf Werksteuerung, Re-Assert je Zyklus). Preview, Deploy, Idempotenz und Kurzlastsanity bestanden. BFCL-Restserie laeuft wieder unter Luefterschutz. Generated by Mistral Vibe. Co-Authored-By: Mistral Vibe <vibe@mistral.ai>
gpu_fan_control
Installs gnai-gpu-fan-control, a root system service that drives the fan
PWM of the configured amdgpu cards (PCI addresses, stable across DRM
renumbering) from their junction temperature.
Rationale and measurements: GNAI-010 section 10.10 — the factory fan curves ramp far too slowly for the cramped dual-GPU layout (SW CTF incident 2026-11-03); with a junction based curve the hot slot holds a verified plateau of 76 celsius under sustained inference load.
Behaviour:
- Linear interpolation between the curve anchors from
defaults/main.yml(idle below 50 celsius rests at PWM 0, full duty is reached by 76 celsius). - Targets are raised immediately, lowered only after falling at least two PWM steps below the current value (falling hysteresis).
- The service re-asserts
pwm1_enable=1every cycle so an amdgpu reload cannot silently restore factory control mid-load. - The EXIT trap restores factory control (
pwm1_enable=2) on every configured card, so a stopped service never leaves a frozen PWM.